Related Searches : Polycarbonate EnclosuresPolycarbonateEnclosuresPolycarbonate GranulesPolycarbonate bottlepolycarbonate profile

Polycarbonate Box/IP67/TIBOX ENCLOSURE

  • TIBOX
  • TB-AT
  • Zhejiang China (Mainland)
  • L/C,T/T
  • Tag:plastic enclosure/box
Post Date : June 03
Product Details
Company Profile

Item specifics

TIBOX
TB-AT
Zhejiang China (Mainland)
L/C,T/T

Specifications

Thermosetting expoxy polyester powder coating in textured RAL 7032 WITH Zinc coated Mounting plate,DOOR 180 DEGREE OPENING

Thermosetting expoxy polyester powder coating in textured RAL 7032 WITH Zinc coated Mounting plate,DOOR 180 DEGREE OPEN.

1.jpg

2.jpg

Company Related ProductsView the Seller's Products
Digital Meter calibrator

Digital Meter calibrator

Digital Meter calibrator

Meter Calibrator,Model:SF-1050W,1P
Accuracy:0.2; LED

Main Function

1.1 5½ digitally display output value, displayed in actual value and in % (5 digits) simultaneously;

1.2 Adopt keyboard or potentiometer to control the increase or decrease of output, the keyboard control split in 100%N, 10%N, 1%N,

0.1%N (N means 3, 4, 5, 6, 7, 8, 9, 10, 15);

1.3 Exterior controller can control the increase or decrease of output outside the calibrator;

1.4 AC/DC output range 0~1000V;

1.5 AC/DC output current range 0~10A; (can do 20, 30Aaccording to customers' requirements)

1.6 Available AC frequency: 50Hz, 60Hz, 400Hz, 45~65Hz (continuous regulation, minimum stepping length 0.1Hz), 350Hz~450Hz

(continuous regulation, minimum stepping length 0.1Hz);

1.7 Output overload has automatic protection, hand reset.

2 Technique Parameter

2.1 Stability: AC<0.03% of full measuring range/5minutes;

DC<0.02% of full measuring range/5minutes;

2.2 AC distortion: <0.5%;

2.3 DC wave coefficient: <0.2%;

2.4 Output frequency accuracy: <0.1%+1 digit;

2.5 Output voltage, current range & accuracy (23±5output value more than 10% measuring range);

2.6 Power consumption: AC voltage 220V, frequency 50Hz, power consumption <150VA;

2.7 Working environment: 5±35; relative humidity: <80%;

2.8 Working duration: continuous;

2.9 Standard cabinet size: 139x480x420mm

2.10 Weight: 16kg

Detail more >>
Digital Meter Calibrator

Digital Meter Calibrator

Digital Meter Calibrator

Meter Calibrator,Model:SF-3020A 3P,
Acuuracy:0.1 LCD

1 Summary

SF-3020A 3P Meter Calibrator is designed in accordance with related national standards & regulations. Without matching an external standard meter, it can automatically or manually calibrate and test class below 0.5 single-phase & 3-phase AC/DC ammeter, AC/DC voltmeter, and power meter. Besides, it can also calibrate frequency meter, phase meter, power factor meter, transducer, power load transformer, and power relay. With standardized cabinet and featured by compact size, light weight, multi-function, high stability & automation, top reliability, easy maintenance, it is an ideal calibrating equipment for meter makers.

2 Main Feature

2.1. Digital frequency modulation, phase modulation, amplitude modulation. Intelligently designed, operation is controlled by the keyboard;

2.2. Voltage output with permanent voltage, current output with permanent current, also with fixed phase & fixed frequency;

2.3. Multi-function standard meter with power, electric energy, AC/DC voltage, AC/DC current standards;

2.4. DC output is separated from AC output;

2.5. Output voltage short circuit, output current open circuit automatically protected, and with voice & light warning;

2.6. LED display with back-light;

2.7. Adopt programming method for calibrating meter, directly display the error and print the testing result;

2.8. With software revising function for standard meter(excluding electric energy meter)

3 Main Technique Parameter

3.1. Voltage output steps/positions: 30V, 100V, 200V, 400V, 600V, with fine regulation 0.01%, each step has 20% allowance;

3.2. Current output steps/positions: 0.1A, 0.5A, 1A, 2.5A, 5A, 10A, 20A, with fine regulation 0.01%, each step has 20% allowance;

3.3. Frequency output range: 45~65Hz, with fine regulation 0.01Hz;

3.4. Phase output regulation: 0~360°, with fine regulation 0.1°;

3.5. Phase angle symmetry degree 120°±0.5°(3P4W voltage); 60°±0.5°(3P3W voltage); current 120°±1°;

3.6. Current & voltage output wave form distortion <0.5%;

3.7. DC voltage and AC voltage is the same, and add DC 75mV step;

3.8. DC current and AC current is the same, and add DC 1mA step;

3.9. DC voltage & current output wave≤1%;

3.10. Output voltage, current, power stability 0.02%/2(minutes);

3.11. Output voltage, current accuracy 0.1%;

3.12. Each phase's rated output capacity of voltage & current is 20VA; output DC voltage, current rated capacity is 15VA;

3.13. Power supply: 220V±10%, 50Hz±1%;

3.14. Working environment: -5~35°; relative humidity≤85%;

3.15. Standardized cabinet size: long350xwide 430xhigh190mm

3.16. Weight: 25kg.

Detail more >>
You may also be interested in:polycarbonate panelpolycarbonate roofingpolycarbonate greenhousePolycarbonate StickerPolycarbonate ScrapPolycarbonate Waste
The informations displayed above are provided by the seller. The authenticity, accuracy and legality of the content are borne by the seller. Please realize that the risks in Internet transactions are objective.
Talk with SupplierX
Hi:
Can I help you?
Contact Supplier

Selected(1/4)Contact or Compare