350W ac/dc switch power supply
1.CE approved
2.100% full-load burn-in test
3.1 year warranty

  • S-350W Series switch powr supply
  • Competitived price and high reliability
  • 105oC Output capacitor
  • AC input power suitable for the world
  • High efficiency and low operation temperature
  • Soft-start current can reduce the AC input impact effeciticly
  • With short-circuit and overload protection
  • Compact size, light weight
  • 100% full-load burn-in test
  • Installed with EMI filter, minimum wave

ModelS-350-5S-350-7.5S-350-12S-350-13.5S-350-15S-350-24S-350-27S-350-48
DC output voltage5V7.5V12V13.5V15V24V27V48V
Output voltage range(Note:2)±2%±2%±1%±1%±1%±1%±1%±1%
Rated output current50A40A29A25.8A23.2A14.6A13A7.3A
Output current range0-50A0-40A0-29A0-25.8A0-23.2A0-1406A0-13A0-7.3A
Wave and noise(Note:3)150mVp-p150mVp-p150mVp-p150mVp-p150mVp-p150mVp-p200mVp-p240mVp-p
Inlet stability(Note:4)±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
Load stability(Note:5)±1%±1%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
DC output power250W300W348W348.3W348W350.4W351W350.4W
Efficiency73%76%74%79%78%81%82%83%
Adjustable range for DC voltage4.5~5.6V6~9V10~13.2V12~15V13.5~18V20~26.4V26~32V41~56V
Input current6.5A/115V 4A/230V
AC inrush current25A/115V 50A/230V
Leakage current<3.5mA/240VAC
Overload protection105%~150% Type: pulsing hiccup shutdown Reset: auto recovery
Over-voltage protection5.75~6.75V9.4~10.9V13.8~16.2V15.5~18.2V18~21V27.6~32.4V33.7~39.2V57.6~67.2V
High-temperature protectionERH3>=65~70°c Fan on, <=55~60°c Fan off,>=80~85°c Cut off ouput(5~15V)~(24~48V)
Setup, rise , hold up time200ms, 100ms, 20ms
Vibration10~500Hz, 2G 10min,/1cycle, Period for 60min, Each axes
Withstand voltageInput and output internal: 1.5KvAC, Input and enclosure:1.5KvAC, Output and enclosure:0.5KvAC
Working temperature and humidity -10°c~+60°c(Refer to output derating curve), 20%~90%RH
Weight1.15Kgs
Safety standardsDesign refer to Ul 1950
EMC standardsDesign refer to FCC Part 15J Part 15 J class A

Note:                                                                                                                                                                1. The testing condition for the paramenter above is: 230VAC input, rated load, 25°c 70% RH. Temperatuer.                

2. Error: include the setting error, line stability and load stability.(Note:5)                                                               

3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.           

4. Inlet woltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.                     

5. Load stability test: The load is from 0% to 100%

   

Company Related ProductsView the Seller's Products
250W switching mode power(S-250-15)

250W switching mode power(S-250-15)

250W switching mode power(S-250-15)

1.250W Switching mode power
2.CE approved
3.Competitived price,good quality,shortest lead time
4.100% burn-in test

  • S-250 Series switching powr suppply
  • Competitived price and high reliability
  • 105oC Output capacitor
  • AC input power suitable for the world
  • High efficiency and low operation temperature
  • Soft-start current can reduce the AC input impact effecticly
  • With short-circuit and overload protection
  • Compact size, light weight
  • 100% full-load burn-in test
  • Installed with EMI filter, minimum wave

ModelS-250-12S-250-13.5S-250-15S-250-24S-250-27S-250-48
DC output voltage12V13.5V15V24V27V48V
Output voltage range(Note:2)±1%±1%±1%±1%±1%±1%
Rated output current20A18A16.6A10.4A9.2A5.2A
Output current range0-20A0-18A0-16.6A0-10.4V0-9.2V0-5.2V
Wave and noise(Note:3)150mVp-p150mVp-p150mVp-p150mVp-p150mVp-p150mVp-p
Inlet stability(Note:4)±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
Load stability(Note:5)±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
DC output power240W243W249W249.6W248.4W249.6W
Efficiency82%83%84%86%86%87%
Adjustable range for DC voltage10~13.2V12~15V13.5~18V20~26.4V26~32V41~56V
AC input voltage range88~132VAC/176~264VAC selected by switch  47~63Hz;254~370VDC
Input current6A/115V 3.5A/230V
AC inrush current20A/115V 40A/230V
Leakage current<3.5mA/240VAC
Overload protection105%~150% Type: pulsing hiccup shutdown Reset: tuto recovery
Temperature coefficient±0.03%/°c(0~50°c)
Setup, rise , hold up time2s, 20ms, 20ms
Vibration10~500Hz, 2G 10min,/1cycle, Period for 60min, Each axes
Withstand voltageInput and output internal: Input and encolsur: 1.5KvAC, Output and enclosure: 0.5KvAC
Isolation resistanceInput and output internal: Input and enclosure, Output and enclosure:500VDC/100MΩ
Working temperature and humidity -10°c~+60°c(Refer to output derating curve), 20%~90%RH
Overall dimension215×115×50mm
Weight1.15Kgs
Safety standardsDesign refer to UL 1950

Note:                                                                                                                                                                  1. The testing condition for the paramenter above is: 230VAC input, rated load, 25°c 70% RH. Temperatuer.                 

2. Error: include the setting error, line stability and load stability.(Note:5)                                                                 

3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.             

4. Inler woltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.                       

5. Load stability test: The load is from 0% to 100%

Detail more >>
250W switching power supply (S-250-27)

250W switching power supply (S-250-27)

250W switching power supply (S-250-27)

1.250W Switching power supply
2.CE approved
3.Competitived price and good quality,shortest lead time
4.100% burn-in test

  • S-250 Series switching powr suppply
  • Competitived price and high reliability
  • 105oC Output capacitor
  • AC input power suitable for the world
  • High efficiency and low operation temperature
  • Soft-start current can reduce the AC input impact effecticly
  • With short-circuit and overload protection
  • Compact size, light weight
  • 100% full-load burn-in test
  • Installed with EMI filter, minimum wave

ModelS-250-12S-250-13.5S-250-15S-250-24S-250-27S-250-48
DC output voltage12V13.5V15V24V27V48V
Output voltage range(Note:2)±1%±1%±1%±1%±1%±1%
Rated output current20A18A16.6A10.4A9.2A5.2A
Output current range0-20A0-18A0-16.6A0-10.4V0-9.2V0-5.2V
Wave and noise(Note:3)150mVp-p150mVp-p150mVp-p150mVp-p150mVp-p150mVp-p
Inlet stability(Note:4)±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
Load stability(Note:5)±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
DC output power240W243W249W249.6W248.4W249.6W
Efficiency82%83%84%86%86%87%
Adjustable range for DC voltage10~13.2V12~15V13.5~18V20~26.4V26~32V41~56V
AC input voltage range88~132VAC/176~264VAC selected by switch  47~63Hz;254~370VDC
Input current6A/115V 3.5A/230V
AC inrush current20A/115V 40A/230V
Leakage current<3.5mA/240VAC
Overload protection105%~150% Type: pulsing hiccup shutdown Reset: tuto recovery
Temperature coefficient±0.03%/°c(0~50°c)
Setup, rise , hold up time2s, 20ms, 20ms
Vibration10~500Hz, 2G 10min,/1cycle, Period for 60min, Each axes
Withstand voltageInput and output internal: Input and encolsur: 1.5KvAC, Output and enclosure: 0.5KvAC
Isolation resistanceInput and output internal: Input and enclosure, Output and enclosure:500VDC/100MΩ
Working temperature and humidity -10°c~+60°c(Refer to output derating curve), 20%~90%RH
Overall dimension215×115×50mm
Weight1.15Kgs
Safety standardsDesign refer to UL 1950

Note:                                                                                                                                                                  1. The testing condition for the paramenter above is: 230VAC input, rated load, 25°c 70% RH. Temperatuer.                 

2. Error: include the setting error, line stability and load stability.(Note:5)                                                                 

3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.             

4. Inler woltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.                       

5. Load stability test: The load is from 0% to 100%