20W LED flood light White warm white 86-265V IP65 CE 2013

  • 0 / 0  
  • Aluminum Alloy
  • LED Light
  • 220-240v
  • Energy Saving
  • Tag:LED Floodlight
Post Date : April 16
Product Details
Company Profile

Item specifics

Aluminum Alloy
LED Light
220-240v
Energy Saving
Square

Specifications

10W LED Flood light Product Description

Model NO.
F10WA
Lumens 950lLm Beam Angle 120° or 60°
Power Consumption 10 W Certified CE & RoHS & C-TICK
Average Life in Hrs 100,000 Bulb Type Epistar/ Bridgelux
Color Rendering Index Ra>80 Equivalent To 80 Watts
Power Factor >0.9 Voltage AC85~240V
Ambient Temperature -40°C~+50°C Dimmable (Option) No
Net Weight 0.65Kg Color Temperature 2700K~8000K /RED/Blue /Green

10W LED Flood light Shape Structure:

Shell Material:Aluminum
Shell Color: silver gray/Black/white(>50PCS)

size:

10W LED Flood Light Illumination Distance/illuminance/Irradiated Area

10W LED Flood light Photomatric Data:

10W LED Flood light installation:

1.Choose the location for your new light fitting giving considerations to the points listed opposite(Mounting method reference).

2.Isolate mains.
3.mark fixing points by using the stirrup fixing holes A B C(Picture 1) and drill three fixing holes.
4.Terminate loose ends of wire to an appropriate IP rated junction box or similar, ensuring the Live, Earth and Neutral polarities are observed(Picture 2).
5.Restore power and test the floodlight.
6.Adjust floodlight head towards the area to be illuminated and lock off using two clamping bolts(Picture 3).

READ THIS FIRST:
Check the pack and make sure you have all of the parts listed on the front of this booklet. If not, contact the outlet where you bought this product.
This product contains glass, care must be taken when assembling, fitting or handling to prevent personal injury or damage to the product.
This light fitting must be installed by a competent person in accordance with the current building and wiring regulations.
As the buyer, installer and/or user of this product it is your own responsibility to ensure that this fitting is fit for the purpose for which you have intended it. NOMO cannot accept any liability for loss, damage or premature failure resulting from inappropriate use.
If in any doubt, consult a qualified electrician.
Switch off the mains before commencing installation and remove the appropriate circuit fuse or lock off MCB.
This unit is suitable for outdoor use.
This product is suitable for installation on surfaces with normal flammability e.g. wood,plasterboard and masonry. It is not suitable for use on highly flammable surfaces (e.g.polystyrene, textiles).
Before making fixing hole(s), check that there are no obstructions hidden beneath the mounting surface such as pipes or cables.
Make sure that the fixings are strong enough to support the considerable weight of the fitting and hold it rigidly.
The floodlight must be positioned so that there is at least 0.5m (500mm) between the bulb and any illuminated surface. Floodlights should be positioned well away from flammable materials.
Do not attach to surfaces which are damp,freshly painted or otherwise electrically conductive (e.g. metallic surfaces).
This product is designed for permanent connection to fixed wiring: this must be a suitable circuit (protected with the appropriate MCB or fuse).
When making connections ensure that the terminals are tightened securely and that no strands of wire protrude. Check that the terminals are tightened onto the bared conductors and not onto any insulation.
This product must be connected to an earth termination.
This product is not intended to be used by children and persons wiath sensory, physical and/or mental impairments that would prevent them from using it safely.
IMPORTANT - if the external flexible cable of this luminaire is damaged it shall be exclusively replaced by a qualified engineer.
You are advised at every stage of your installation to double-check any electrical connections you have made. After you have completed your installation there are electrical tests that should be carried out, these tests are specified in the current GB/T wiring and building regulations. If in doubt, consult a qualified electrician.
Do not carry or lift the floodlight by the mains supply cable.
LED Flood Lights details:
LED flood light,LED Street Lights, China led flood light and led Street lighting products manufacturer
Company Related ProductsView the Seller's Products
10W LED flood light White warm white 86-265V IP65 CE 2013

10W LED flood light White warm white 86-265V IP65 CE 2013

10W LED flood light White warm white 86-265V IP65 CE 2013

10W LED Flood light Product Description

Model NO.
F10WA
Lumens 950lLm Beam Angle 120° or 60°
Power Consumption 10 W Certified CE & RoHS & C-TICK
Average Life in Hrs 100,000 Bulb Type Epistar/ Bridgelux
Color Rendering Index Ra>80 Equivalent To 80 Watts
Power Factor >0.9 Voltage AC85~240V
Ambient Temperature -40°C~+50°C Dimmable (Option) No
Net Weight 0.65Kg Color Temperature 2700K~8000K /RED/Blue /Green

10W LED Flood light Shape Structure:

Shell Material:Aluminum
Shell Color: silver gray/Black/white(>50PCS)

size:

10W LED Flood Light Illumination Distance/illuminance/Irradiated Area

10W LED Flood light Photomatric Data:

10W LED Flood light installation:

1.Choose the location for your new light fitting giving considerations to the points listed opposite(Mounting method reference).

2.Isolate mains.
3.mark fixing points by using the stirrup fixing holes A B C(Picture 1) and drill three fixing holes.
4.Terminate loose ends of wire to an appropriate IP rated junction box or similar, ensuring the Live, Earth and Neutral polarities are observed(Picture 2).
5.Restore power and test the floodlight.
6.Adjust floodlight head towards the area to be illuminated and lock off using two clamping bolts(Picture 3).

READ THIS FIRST:
Check the pack and make sure you have all of the parts listed on the front of this booklet. If not, contact the outlet where you bought this product.
This product contains glass, care must be taken when assembling, fitting or handling to prevent personal injury or damage to the product.
This light fitting must be installed by a competent person in accordance with the current building and wiring regulations.
As the buyer, installer and/or user of this product it is your own responsibility to ensure that this fitting is fit for the purpose for which you have intended it. NOMO cannot accept any liability for loss, damage or premature failure resulting from inappropriate use.
If in any doubt, consult a qualified electrician.
Switch off the mains before commencing installation and remove the appropriate circuit fuse or lock off MCB.
This unit is suitable for outdoor use.
This product is suitable for installation on surfaces with normal flammability e.g. wood,plasterboard and masonry. It is not suitable for use on highly flammable surfaces (e.g.polystyrene, textiles).
Before making fixing hole(s), check that there are no obstructions hidden beneath the mounting surface such as pipes or cables.
Make sure that the fixings are strong enough to support the considerable weight of the fitting and hold it rigidly.
The floodlight must be positioned so that there is at least 0.5m (500mm) between the bulb and any illuminated surface. Floodlights should be positioned well away from flammable materials.
Do not attach to surfaces which are damp,freshly painted or otherwise electrically conductive (e.g. metallic surfaces).
This product is designed for permanent connection to fixed wiring: this must be a suitable circuit (protected with the appropriate MCB or fuse).
When making connections ensure that the terminals are tightened securely and that no strands of wire protrude. Check that the terminals are tightened onto the bared conductors and not onto any insulation.
This product must be connected to an earth termination.
This product is not intended to be used by children and persons wiath sensory, physical and/or mental impairments that would prevent them from using it safely.
IMPORTANT - if the external flexible cable of this luminaire is damaged it shall be exclusively replaced by a qualified engineer.
You are advised at every stage of your installation to double-check any electrical connections you have made. After you have completed your installation there are electrical tests that should be carried out, these tests are specified in the current GB/T wiring and building regulations. If in doubt, consult a qualified electrician.
Do not carry or lift the floodlight by the mains supply cable.
LED Flood Lights details:
LED flood light,LED Street Lights, China led flood light and led Street lighting products manufacturer
Detail more >>
80W LED flood  light White warm white RGB 86-265V IP65 CE 2013

80W LED flood light White warm white RGB 86-265V IP65 CE 2013

80W LED flood light White warm white RGB 86-265V IP65 CE 2013

80w led flood light Description
Model NO.
F80WA
Lumens 7200lLm Beam Angle 120° or 60°
Power Consumption 80 W Certified CE & RoHS & C-TICK
Average Life in Hrs 100,000 Bulb Type Epistar/ Bridgelux
Color Rendering Index Ra>80 Equivalent To 600 Watts
Power Factor >0.9 Voltage AC85~240V
Ambient Temperature -40°C~+50°C IP Grade IP65
Net Weight 6.5Kg Color Temperature 2700K~8000K /RED/Blue /Green
80w led flood light Shape Structure:

Shell Material:Aluminum Shell

Color: silver gray/Black/white(>50PCS)

Size:

80w led flood light Illumination Distance/illuminance/Irradiated Area

80w led flood light fixtures Photomatric Data:

80w led flood light fixtures installation:

1.Choose the location for your new light fitting giving considerations to the points listed opposite(Mounting method reference).

2.Isolate mains.
3.mark fixing points by using the stirrup fixing holes A B C(Picture 1) and drill three fixing holes.
4.Terminate loose ends of wire to an appropriate IP rated junction box or similar, ensuring the Live, Earth and Neutral polarities are observed(Picture 2).
5.Restore power and test the floodlight.
6.Adjust floodlight head towards the area to be illuminated and lock off using two clamping bolts(Picture 3).

LED flood light,LED Street Lights, China led flood light and led Street lighting products manufacturer
Detail more >>
You may also be interested in:white led flood lightLED lights warm whiteled flood light VOL-FL20W CE ROHShigh power IP65 outdoor led flood light20w led flood lightCool White Led Flood Light
The informations displayed above are provided by the seller. The authenticity, accuracy and legality of the content are borne by the seller. Please realize that the risks in Internet transactions are objective.
Talk with SupplierX
wanjun w:
Can I help you?
Contact Supplier

Selected(1/4)Contact or Compare