Related Searches : Clamp Mountt mount adaptermount adapterTube Clamp Adapterclamp-on adapterwall mount pipe clamp

MOUNTING CLAMP ADAPTER

  • POWERY
  • Shandong China (Mainland)
  • Tag:flat corner brace,bed brace,speed brace
Post Date : May 04
MEMBRANE SWITCH KEYBOARDS
Membrane Switch Panels Manufacturer
Worldwide Free Shipping
Fast Turnaround in 24 Hours
High Quailty
Product Details
Company Profile

Item specifics

POWERY
Shandong China (Mainland)

Specifications

MOUNTING CLAMP ADAPTER

These Clamps are designed to adapt to circular and octagonal concrete steel pole.Alternatively can be adapted to wood poles at the end user option.

The PC0150H clamps are heavy duty type band.They are designed with forged reinforcing rib/stiffener on its comer bond for extra flexural strength, used for attaching brace for heavy primary line cross arm or side arm construction.

The PC0150 series are used for used for light cross arm or side arm primaey line construction.

Both clamps can be used for attaching extension arm,aerial cable attachment on straight run,attaching cable on comer run,down guying or deadend guying application.

18  MOUNTING CLAMP ADAPTER.jpg

Company Related ProductsView the Seller's Products
ACSR aluminium alloy stranded conductor steel reformed BS3242

ACSR aluminium alloy stranded conductor steel reformed BS3242

ACSR aluminium alloy stranded conductor steel reformed BS3242

ACSR

ACSR aluminium alloy stranded conductor steel reformed BS3242

ACSR aluminium alloy stranded conductor steel reformed BS3242

ACSR aluminium alloy stranded conductor steel reformed BS3242 ACSR aluminium alloy stranded conductor steel reformed BS3242


We can supply this conductor according to different recognized standards, such as IEC61089, BS215, ASTM B232, CSA C49, DIN48204, JIS C3110, customer special specification also can be satisfied.
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power
Applications
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

Construction
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.

Specifications
ACSR bare conductor meets or exceeds the following ASTM specifications:

B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

Notes
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

Detail more >>
ACSR aluminium conductor steel reformed b232

ACSR aluminium conductor steel reformed b232

ACSR aluminium conductor steel reformed b232

ACSR

ACSR aluminium conductor steel reformed b232

ACSR aluminium conductor steel reformed b232

ACSR aluminium conductor steel reformed b232 ACSR aluminium conductor steel reformed b232


We can supply this conductor according to different recognized standards, such as IEC61089, BS215, ASTM B232, CSA C49, DIN48204, JIS C3110, customer special specification also can be satisfied.
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power
Applications
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

Construction
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.

Specifications
ACSR bare conductor meets or exceeds the following ASTM specifications:

B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

Notes
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.