  • SRDSC-200
  • Tag:Differential scanning calorimeter (DSC), analysis instruments
  • Supplier - Serve Real Instruments Co.,Ltd
  • China (Mainland)China (Mainland)
  • US$1 Million - US$2.5 Million
  • 11 - 50 People
  • Manufacturers
  • North America,South America,Southeast Asia,Africa,Mid East,Western Europe
  •     
  • skype
  • Mr.Chung
  • 86-21-61480182
Post Date : November 06
Product Details
Company Profile

Item specifics

SRI
18 months
5-10 days
SRDSC-200
T/T, Paypal
China (Mainland),Jiangsu

Specifications

Product introduction:
DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control. DSC research and development includes the following field: glass transition temperature, melting point, cold crystallization, crystallization, phase transition, oxidation induction time (OIT).

Main Features:
1. New designed oven structure ensures high resolution and good stability of base line;
2. Air flow meter may control the air flow rate accurately; the test data can be recorded into the database directly;
3. The instrument is bilateral control, may be controlled by both main frame and software. User-friendly interface, easy operation.


Technical parameters:
1. DSC range: 0~±500mW
2. Temperature range: room temperature~600°C~room temperature air-cooled

3. Heating rate: 1~80°C/min Cooling rate: 1 ~ 10 °C / min
4. Temperature resolution: 0.1°C
5. Temperature fluctuations: ±0.1°C
6. Temperature repeatability: ±0.1°C
7. DSC noise: 0.01μW
8. DSC resolution: 0.01μW
9. DSC accuracy: 0.1μW
10. DSC sensitivity: 0.1μW
11. Control Mode: Rising temperature, constant temperature(full automatic programmed control)
12. Curve scanning: Rising scan, *cooling scan
13. Atmosphere control: Embedded digital flow meter & Software control
14. Display: 24 bit color 7 inches LCD touch screen display

15. Data interface: standard USB connector
16. Parameter standard: equipped with standard material, with a key calilbration function, the user may correct temperature and heat enthalpy
17. Note: * for selecting projects, all technical indicators can be adjusted according to customers' demand

Company Related ProductsView the Seller's Products
Differential scanning calorimeter (DSC)

Differential scanning calorimeter (DSC)

Differential scanning calorimeter (DSC)

Product introduction:
DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control. DSC research and development includes the following field: glass transition temperature, melting point, cold crystallization, crystallization, phase transition, oxidation induction time (OIT).

Main Features:
1. New designed oven structure ensures high resolution and good stability of base line;
2. Air flow meter may control the air flow rate accurately; the test data can be recorded into the database directly;
3. The instrument is bilateral control, may be controlled by both main frame and software. User-friendly interface, easy operation.


Technical parameters:
1. DSC range: 0~±500mW
2. Temperature range: room temperature ~ 800 °C air-cooled
3. Heating rate: 1 ~ 80°C/min
4. Temperature resolution: 0.1 °C
5. Temperature fluctuations: ±0.1°C
6. Temperature repeatability: ±0.1°C
7. DSC noise: 0.01μW
8. DSC resolution: 0.01μW
9. DSC accuracy: 0.1μW
10. DSC sensitivity: 0.1μW
11. Control Mode: Rising temperature, constant temperature(full automatic programmed control)
12. Curve scanning: Rising scan, *cooling scan
13. Atmosphere control: Embedded digital flow meter & Software control
14. Color: 24 bit 7 inches LCD touch screen display

15. Data interface: standard USB connector
16. Parameter standard: equipped with standard material, with a key calibration function, the user may correct temperature and heat enthalpy
17. Note: * for selecting projects, all technical indicators can be adjusted according to customers' demand

Detail more >>
DTA High temperature differential thermal analyzer

DTA High temperature differential thermal analyzer

DTA High temperature differential thermal analyzer

Description

DTA:Differential Thermal Analysis is a technique which can measure the temperature difference and temperature relationship between the sample and the reference material in the process control temperature. Differential thermal analysis curves can describe the relationship of the temperature difference △T changes with the temperature or time between the sample and the reference material. During the DTA experiment, the sample temperature changes due to the endothermic or exothermic effect of the phase transition or reaction. Such as, phase transition, melting, crystalline structure transition, boiling, sublimation and evaporation, dehydrogenation, cleavage reaction or decomposition reaction, oxidation or reduction reaction, the destruction of lattice structure and the other chemical reaction.

Technical parameters:
1. The temperature range: room temperature ~ 150 °C
2. measuring range: 0~±2000μV
3. DTA precision: ±0.1μV
4. Heating rate: 1 ~ 80°C/min
5. Temperature resolution: 0.1°C
6. Temperature accuracy: ±0.1°C
7. Temperature repeatability: ±0.1°C
8. Temperature control:
Warming temperature: program control
(User can adjust parameters according to requirements)
Cooling temperature: air-cooled program control
Constant temperature: program control (User can set the time arbitrarily)
9. Body Structure: Use the structure of the cover to replace the traditional lifting furnace, with high precision and easy operation.
10. Atmosphere control: (optional) gas flow meter, atmosphere conversion device
11. Data interface: standard USB connector, supporting data line and operating software
12. Display: 24 bit color 7 inch LCD touch screen display
13. Parameters of Standard: Equipped with reference substances, with a key calibration fuction (User can correct the temperature)
14. Baseline adjustment: Users can adjust the baseline by changing baseline slope and intercept
15. Work power: AC 220V 50Hz