Related Searches : cable series LTF type asphalt coating machineSwivel type PD-160F160 Type GrinderBW-160 type mud pumpLTF-2421 Warning light160T c-type injection machine

Exera Pleuravideoscope LTF Type 160

Post Date : January 12
Product Details
Company Profile
Inquiry Records(1)

Item specifics

Specifications

PLEURAVIDEO SCOPE LTF TYPE 160

LTF-160 The pleurascope that makes medical thoracoscopy under local anaesthesia easier than ever . Main Features Pleuravideoscope for single port procedure under local anaesthesia. Semi-rigid design. Easy observation of the pleural cavity. 2.8 mm channel allows suction of even small effusions and biopsy pleura with flexible instruments. Simple handling - very similar to flexible bronchoscope. EVIS EXERA semi-rigid pleuravideoscope LTF-160 The LTF-160 has been specially designed to simplify and streamline medical thoracoscopy (pleuroscopy) under local anaesthesia with a slim, flexible design that enables procedures to be quickly performed. Specifications Optical System Field of view 120° Direction of view 0° (forward viewing) Depth of field 3 to 100 mm Distal End Outer diameter 7.0 mm Insertion tube Outer diameter 7.0 mm Bending Section Angulation range Up 160°, Down 130° Working length 270 mm Total Length 520 mm Instrument Channel Inner diameter 2.8 mm Minimum visible distance 3 mm from distal end High Frequency Compatibility YES Autoclave Compatibility YES Scope ID Function YES Laser Compatibility YAG, LD
Company Related ProductsView the Seller's Products
Exera Xenon Light Source CLV-160

Exera Xenon Light Source CLV-160

Exera Xenon Light Source CLV-160

CLV-160 EVIS EXERA XENON

With its improved condenser lens design and powerful 300W xenon lamp, the EVIS EXERATM 160 Series' dedicated light source, the CLV-160, is able to generate 30% more light intensity than its predecessor, the CLV-U40. This new design and power assures clear, accurate observation even of distant points. When combined with the CV-160 video system center, the CLV-160 provides a system that is a full 80mm narrower and 35% smaller than previous Olympus models, allowing for the entire system to be installed on a dedicated cart together with a video monitor and other ancillary equipment. Specification CLV-160 EVIS EXERA Xenon light source Automatic brightness control Automatic brightness control method Servo-diaphragm method Automatic exposure 17 steps Air feeding Pump Diaphragm pump Pressure switching 4-level switching by switches (OFF, L, M, H) Water feeding Method Air pressurization or detachable water container Indicators on front panel Emergency lamp Reports absence of emergency lamp, disconnection and use of emergency lamp Filter Identifies a special-purpose filter setting Setting memory - Settings (exept filter setting) are stored by an internal battery even when the power is turned OFF Illumination Lamp Xenon short-arc lamp (ozone-free) 300W Average lamp life Approximately 500 hours on continuous use (on intermittent use, the lamp life may vary slightly) Ignition method Switching regulator Brightness adjustment Light-path diaphragm control Cooling Forced-air cooling Color conversion Possible by using exchangeable filter Emergency lamp Halogen lamp 12V 100W Average emergency lamp life Approximately 100 hours Classification (medical electrical equipment) Type of protection against electric shock Class I Degree of protection against electric shock of applied part Type BF applied part (the applied part where classification types are not marked is Type BF applied part) Power supply Voltage NTSC 100-120 V AC, PAL 220-240 V AC Frequency 50/60 Hz Input current NTSC 5 A, PAL 3 A Size Dimensions 370 (W) x 135 (H) x 420 (D) mm Weight 15 kg
Detail more >>
Exera Vidio System Center CV-160

Exera Vidio System Center CV-160

Exera Vidio System Center CV-160

CV-160 VIDEO SYSTEM CENTER

Designed exclusively for the EVIS EXERATM 160 Series, the CV-160 features a leading-edge video signal processing technology configured to frequency components specifically suited for endoscopic images, allowing it to enhance details while simultaneously suppressing noise. The result is a more detailed image that makes it easier to spot minute tissue textures and subtle color variations on the mucous membrane. As for versatility, the CV-160 video system center can also accommodate EVIS EXERATM video bronchoscopes so you can use the same system for both gastrointestinal endoscopy and bronchoscopy. It's also fully compatible with the EVIS 100/130/140 Series gastrointestinal scopes. CV-160 video system center Observation Video signal output VBS composite, Y/C, RGB; simultaneous output is possible. White balance By pressing the white balance switch on the front panel, automatic white balance can be performed. After initialization, white balance settings are retained in memory for EVIS EXERA 160 Series scopes. Standard color chart output The color bar image can be displayed using the "Color Bar" key on the keyboard. Digital communication port Ethernet (100BASE-TX) Color tone adjustment "CHROMA" control: ±7 steps, "R" control: ± 7 steps, "B" control: ± 7 steps Automatic gain control (AGC) The image can be electrically amplified when the light is inadequate due to the distal end of the video scope being too far from the subject. Contrast Normal Contrast mode: Normal image; Low Contrast mode: The dark areas are lighter and the light areas are darker than in a normal image; High Contrast mode: The dark areas are darker adn the light areas are lighter than in a normal image. Iris mode selection Average: Normal observation; Peak: When focusing on and/or observing a small bright area. Structure enhancement setting The detailed patterns and edges of endoscopic images are emphasized electronically to increase image sharpness. The structure enhancement level can be switched between "Low", "Medium" and "High". Edge enhancement setting The edges of endoscopic images are emphasized electronically to increase image sharpness. The edge enhancement level can be switched between "Low", "Medium" and "High". Image size selection The size of endoscopic images can be changed using the "Image Size" key on the keyboard or endoscope switch. Default reset The following settings can be restored by pressing the "RESET" switch on the front panel: Image Source, Iris, Enhancement, Color, AGC, Display mode, Contrast, Printer Lock, Keyboard mode, Printer mode, Printer QTY. Freeze screen display A stationary image can be displayed using the endoscope switch, keyboard or OVC switch. Documentation Remote control The following ancillary equipment can be controlled by the endoscope remote switch, the front panel and the keyboard (only the specified device types are valid): Monitor, VTR, Video printer equipment, Digital video cassette recorder, Flushing pump. Patient data The following data and modes can be displayed on the video monitor using the keyboard: 1) ID number 2) Patient name 3) Sex, age 4) Date of birth 5) Date/time (built-in clock, stopwatch) 6) Frame number 7)VTR condition 8)Picture quality selection 9)Physician 10)Comments Pre-procedural patient data For a maximum of 40 patients. 1) ID number 2) Patient name 3) Sex, age 4) Date of birth 5) Physician Recalling and registered scope information (scope ID function) The following scope-related data stored in the memory chip of the scope can be recalled and displayed on the screen: Scope Model, Serial No., Comments, Cumulative Uses, Check Period, Service Contract, Warranty Date, Owner, Customer ID No., ID Ver. Image storage and retrieval Monitor output Using the monitor output switch on the front panel, it is possible to select an image from the endoscope of ancillary equipment for display on the monitor. Memorization of selected setting The following settings on the front panel are retained even when the power is turned OFF: Color, Enhancement, White balance, Iris. Classification (medical electrical equipment) Type of protection against electric shock Class I Degree of protection against electric shock of applied part Type BF applied part (the applied part where classification types are not marked is Type BF applied part). Power supply Voltage NTSC 100-120 V AC, PAL 220-240 V AC Frequency 50/60 Hz Input current NTSC 1.0 A, PAL 0.5 A Fuse rating 3.15 A, 250 V Size Dimensions 370 (W) x 72 (H) x 420 (D) mm Weight 8 kg
Detail more >>
You may also be interested in:160KW Cummins Soundproof Type GeneratorJL160type high pressure Pressing MachineAmerican type cutting torch G01-160Q43-160 Crocodile type metal shears160KW open type diesel generatorLTF91 Strobe Light Bar
Talk with SupplierX
Hi:
Can I help you?
Contact Supplier

Selected(1/4)Contact or Compare