Related Searches : GZG Pipe Bungle DryerGZG series Vibrating Feeder

GZG

  • 10 Pole/Poles
  • ShangHai
  • OPEN
  • GZG
  • Zhejiang China (Mainland)
  • Tag:Distribution box, power distribution box
Post Date : April 21
Product Details
Company Profile

Item specifics

ShangHai
OPEN
GZG
Zhejiang China (Mainland)
20000 Piece/Pieces per Week
L/C,D/P,T/T

Specifications

Technical force is abundant, detection equipment, and has many national patents.

Mostly Purpose
GZG series intelligent high-frequency switch dc power system applies ark such power substation electric equipment, relay protection device dc power systems, control, communications, a signal to protect and dc power plant etc lighting, the power equipment.
This product USES high-frequency switch rectifier equipment has the advantages of small size, light quality, technical index is superior, modular design, N + 1 hot backup, convenient "four control", etc. Products for battery and tributaries power cupboard, intelligent management, ensure the battery life. Equipped with central monitors, remote function, improve the reliability of the dc system and automation level.
This product accords with JB/T5777.4-2000 the power system, dc power equipment general technical conditions and safety requirements.

Panel labels

Serial number

Labels

note

1

Charging electric current

signage

2

Always load current

signage

3

Current and voltage

signage

4

Mother charged voltage

signage

5

Insulation warning

Light zhong

6

Molten core fusing batteries

Light zhong

7

Battery failure

Light zhong

8

Module fault

Light zhong

9

Mother abnormal voltage control

Light zhong

10

Exchange voltage-absent

Light zhong

11

Manual automatic conversion

signage

12

Flashes instructions

signage

13

Flash test

signage

14

Mother charged voltage regulation

signage

15

Ac input

signage

16

Charging output device

signage


1, cabinet put oneself in another's position for the composite structure
2, rechargeable battery, floating device USES multiple high-frequency rectifier module in parallel, N + 1 backup, automatic flow
3 and monitor the perfect function and high intelligence, with big screen display, light night crystal characters, or use touch-screens. Warning The intelligent design, the system components, communication module, dc power rectifier, realize the local feed and remote control parameters, the main monitoring module are: open/shutdown, charging ways, output voltage regulation, output current limiting point setting, dual exchange automatically switch, battery automatic management etc
4 and monitoring system is equipped with standard rs-five 3232cadets or RS485 interface, and superordination machine networking, "four control function.
5 and automatic management of battery and maintenance of the battery voltage, real-time detection, recharge current, automatic control and regular maintenance are floating filling are filling.
Six, can according to user needs with temperature compensation function.
7, in any case, when the grid solution, the ac power lost electricity, battery can uninterrupted power supply, ensure to busbar protection, automatic device, power control and high frequency switching power supply is operating.

GZG

Company Related ProductsView the Seller's Products
GZD(W)

GZD(W)

GZD(W)

Technical force is abundant, detection equipment, and has many national patents.

Mostly Purpose
GZD (W) series (microcomputer control) d.c.power supply cabinet applied in large and medium power substation, as normal operation, and the pressure switch points and brake, relay protection and automatic control, lighting, lighting and sound signal for dc power supply, etc. Also can be used in metallurgy, railway. Mine, petrochemical, post and telecommunications, communication, medical and health, bank, hotel, high-rise buildings and computer network industries for dc power supply, Microcomputer control dc power ark can be used for the unattended, remote monitoring of the concentration of substations and other industry, power plant, the dc power supply.
The product conforms to T5777 JB /. 4-2000 the power system, dc power equipment general technical conditions and safety requirements.

Type Meaning

Product model

Serial number

Specifications (kind of)

Use scope

GZD(W)30

The aggregate-organ, batteries, single bus, two double charging output device, step-down float charging circuit

10

Plants or large substation

GZD(W)31

The aggregate-organ, batteries, single bus, two double charging output device, step-down float charging circuit

10

Plants or large substation

GZD(W)32

The aggregate-organ, batteries, double-bus configuration points, two double battery charging output device. Float

20

12KV ~ 220KV power substation and small

GZD(W)33

The aggregate-organ, batteries, double generatrix, two double charging output device. Float charging

20

12KV ~ 220KV power substation and small

GZD(W)34

The aggregate-organ, batteries, double generatrix, two triplet output charge float charging device

20

12KV ~ 220KV power substation and small

GZD(W)35

The aggregate-organ, batteries, double generatrix, two triplet output charge float charging device

20

12KV ~ 220KV power substation and small

GZD(W)40

Two pairs of battery, the double-bus configuration points, two double output devices, without charging float charging circuit. Antihypertensive

10

Important plant or large substation

OZD(W)41

Two pairs of battery, the double-bus configuration, two double battery charging output device. Float

12

12KV ~ 220KV power substation and small

GZD(W)42

Two pairs of battery, the double-bus configuration points, two double battery charging output device. Float

10

Important plant or large substation

GZD(W)43

Two pairs of battery, the double-bus configuration, two triplet output charge float charging device

12

12KV ~ 220KV power substation and small

Main function
1 and specifications: this series product has 10 types of hundreds of specifications, can fully satisfy large small-and-middle-scale power plant and substation and industries of dc power demand.
2 and reliable operation: exchange double input switch. This product has two charging, float snake charging device standby, switching system.
3 and stable operation: this product anti-jamming performance is good, steady flow, elegant high precision, small ripple.

Technic Parameter

Input voltage

Three-phase ac380V+-10%,50HZ+-5%

Output dc voltage rating

24,48,110,220V

Output dc current ratings

5,8,10,15,20,30,40,50,80,100,150,200,250,300,350,400A

Battery power rating

10,20,38,40,50,60,65,80,100,150,200,250,300,400,500,600,800,1000AH

Voltage regulation scope

Output dc voltage rating

24V

48V

110V

220V

Floating charging pressure regulating scope

21~28

43~57

99~130

198~260

Are charging pressure regulating scope

27~31

54~62

125~140

198~286

The charging pressure regulating scope

21~36

43~70

99~162

187~310

Dc current output adjusting range

Ratings 0 ~ 100%

Voltage accuracy

+-1%

Steady flow accuracy

+-1%

Ripple coefficient

%

The noise

55DB

The main transformer

70°C

Working mode

Continuous work

Efficiency,

90%

Protective level

IP20~IP30

GZD(W)

Detail more >>
GGD

GGD

GGD

Technical force is abundant, detection equipment, and has many national patents.

Mostly purpose
GGD communication equipment is suitable for low voltage distribution switch power substation, power users as mining enterprises etc, rated voltage isolator ac 380V rated current 3150A to the distribution system in power distribution equipment, lighting and the energy conversion, distribution and control. The products, high abilities which are rated current of 50KA short. Line, flexible, practical, easy combination of novel structure, etc. This product is the representative assembly type fixed panel switchgear.
The product conforms to the low voltage switchgear equipment GB7251 IEC60439, the low voltage switchgear equipment and control equipment etc.

Technic Parameter
1, the main technical parameters, see table 1
2 and auxiliary circuit
Auxiliary circuit design scheme and power utilization points scheme in two parts.
Line 3, mistress
In 1500A and rated current below the single copper platoon bus. More than 1500A rated current when using double copper platoon bus. The surface generatrix of overlapped by honing tin process.
1) level busbar selection (table 2)
2) neutral earthing selection bus (see table 3)
3) electrical components
A, GGD ark mainly adopts already can batch production of domestic electrical components. As such, DZ20, DWI5 guijia breaker can also choose must, AE, M, F, plastic shell breaker selection, and other advanced CML of electrical components.
B, HDI3BX and HSI3BX type operating knife switch is designed for unique structure and design of the special components, it has changed the organization mode of operation, retain the old products, it is a kind of utility of electrical components.
C, such as design department, choose according to user's needs more excellent performance, technology more advanced new electrical components, because install ark, GGD flexible for updating the electrical components manufacturing and installation of caused difficulties.
D, in order to further enhance the ability of dynamic stability, the circuit of the ark in GGD busbar type combined-type generatrix ZMJ clips and support. By high intensity, busbar clip high-fire-retardant PPO composite thermal insulation of forming, high strength, good self-extinguishing RTV silicone compound, unique structure, just adjust block can be easily combination between blocks of single or double generatrix of busbar folder. Insulation support is sleeve mould structure, low cost, high strength, solve the old product creep age distance of insufficient.

model

The rated voltage V

Rated A

Rated short open circuit current KA

The current (rated short-term 1S) KA

Rated current KA peak tolerance

GGD1

380

A 100

15

15

30

B 600(630)

C 400

GGD2

380

A 1500(1600)

30

30

63

B 1000

C 600

GGD3

380

A 3150

50

50

105

B 2500

C 2000

Rated current A

Copper bus specifications MM

400

40×4

630

50×5

1250

60×10

1600

80×10

2000

2×(60×10)

2500

2×(80×10)

3150

2×(100×10)

Phase wire was the cross-sectional area

PE (N) line was the cross-sectional area

500~720

40×5

1200

60×6

>1200

60×10

GGD

GGD1

Detail more >>
The informations displayed above are provided by the seller. The authenticity, accuracy and legality of the content are borne by the seller. Please realize that the risks in Internet transactions are objective.