Related Searches : GAC Speed Controller ESD5330EFORD Speed control motorUnit Speed Control MotorBrake Speed Control MotorOriental Speed Control MotorsGAC Speed Controller

GAC ESD5330 Electric Governor/Speed Controller/motor speed controller/electronic speed control/gac speed control

  • 1 Piece/Pieces
  • Zhejiang China (Mainland)
  • 2000 Piece/Pieces per Day
  • T/T,Western Union
  • speed control motor/dc controller,esc speed controller/dc motor controller
Post Date : April 22
Product Details
Company Profile

Item specifics

Zhejiang China (Mainland)
2000 Piece/Pieces per Day
T/T,Western Union

Specifications

GAC ESD5330 Elc Govs designed to precisely control engine speed and provide fast precise response to transient engine loads.

Product Description

GAC ESD5330 INTRODUCTION
The ESD5330 Series speed control unit is designed to precisely control engine speed and provide fast precise response to transient engine loads. This speed control is intended to be used with all GAC Actuators including the ACB2000. A complete closed loop control system is formed with the addition of a magnetic pickup signal sensing engine speed and 24 Volt DC power.

The ESD5330 Series has several special built in features:
*  A Two Element Speed Switch (overspeed sensing and crank termination)
*  Speed Ramping from Idle to Operating Speed
*  A unique actuator power drive circuit
Other standard features include: adjustable Droop, Accessory inputs for load Sharing, Variable Speed Governing, protection against reverse battery voltage and transient voltages and a fail safe design in the event of loss of speed signal or battery supply.

ESD5330 SERIES SPEED CONTROL UNIT
ESD5330------Standard Unit, 24 Volt operation ESD5331----------use w/EFC Actuator
ESD5330-12--------------------12 Volt operation ESD5331-12------use w/EFC Actuator

PERFORMANCE
Isochronous Operation/Steady State Stability: ± 0.25% or better
Operation Speed Range: 1K-7.5K Hz continuous
Speed Drift With Temperature: ± 1% maximum
Idle Speed Adjust Range: 25-85% of rated speed
Droop Range: Adjustable from 0-5% for a 1.5 A actuator current change
Speed Trim Range: ± 200 Hz
Remote Variable Speed Range: 25 to 100% of rated speed
Speed Ramp Time: Acceleration adjustment range 266 Hz/Sec to 1300 Hz/Sec
Deceleration adjustment range 250 Hz/Sec to 1000 Hz/Sec
Starting Fuel Adjustment
0-1.5A: 120, 175, 225, 275 Actuators/SW2-7 OFF
0.3-4A: 2000 A
Overspeed Set Point: 2400 Hz to 8300 Hz
Crank Termination Set Point: 200 Hz to 2050 Hz
Terminal Sensitivity
H: -105 Hz, ± 15Hz / Volt @ 5.0K impedance
M: -130 Hz, ± 15Hz / Volt @ 1 M impedance
K: -685 Hz, ± 40 Hz / Volt@ 225K impedance
N: +1000 Hz, ± 50 Hz / Volt@ 8 K impedance

ENVIRONMENTAL
Ambient Operating Temperature Range: -40· +185· F (-40· to ~+85º C)
Relative Humidity (Noncondensing): Up to 95%
All Surface Finishes: Fungus proof & corrosion resistant

INPUT POWER-Nominal Ratings
DC Supply: 24 ± 20% VDC battery systems ( transient and reverse voltage protected)
Maximum Continuous DC Supply Voltage: 32 Volts
Polarity: Negative ground (Case isolated)
Power Consumption (Engine Stopped): 100 MA (No actuator current)
Speed Sensor Signal: 0.5-120 Volts RMS
Maximum Actuator Current: Internally limited to 9A continuous
Maximum Current, Speed Switch Contact (Terminals 1-6): 6 Amps

RELIABILITY
Vibration: 1G @ 20-100Hz
Shock: 10 G (11 ms)
Testing: 100% Functionally tested

PHYSICAL
Dimensions: See FIGURE 1 Wiring Diagram and Outline (page 3)
Weight: 2.0 Ibs (0.91 grams)
Mounting: Any position, vertical preferred

Company Related ProductsView the Seller's Products
CUMMINS Delay Start And Speed Regulator Governor 4914090 / 4914091 /Cummins Speed Controller 4914090 / 4914091

CUMMINS Delay Start And Speed Regulator Governor 4914090 / 4914091 /Cummins Speed Controller 4914090 / 4914091

CUMMINS Delay Start And Speed Regulator Governor 4914090 / 4914091 /Cummins Speed Controller 4914090 / 4914091

CUMMINS Delay Start And Speed Regulator Governor 4914090 / 4914091
Speed Controller for Cummins Engine

CUMMINS Delay Start And Speed Regulator Governor 4914090 / 4914091/dc motor speed controller/ac motor speed controller

Product Description

CUMMINS POWER
Environment Protection Products
------Cummins Diesel Generator Sets
With Low Smoke Displacement
Delay Start And Speed Regulator

1. Application Features
1.1. Low smoke displacement, soft noise
Meet the demand of environment protection imp rive people´ S
Feeling.
1.2. Easily start in cold, plateau and Ww pressure areas,
Especially for N-G-250kw and K-G-300kw sets.
1.3. High ability to anti-disturbance Stable operation due to the large power walkie-talkie·
1.4. Actuator can not be damaged in case of short circuit due to
The output protector.
1.5. Diesel with water pump cam start with wad, the range of round per minute cam be ± 600, that is 1000-1200 rpm.
2. Principles
The oil valve of the Cummins speed regulator is totally
Open and if the supercharger low—speed and with little
Air input, So it is difficult to ignite the fuel and cannot
Completely ignite and have thick smoke displacement. It starry400—1200rpm, It need 3-5or 10-20 minute
To accelerate.
It can easily start if we decrease the oil input. After it start, then increase´ The oil input, the speed and the diesel generator temperature will increase gradually. Thus, the smoke displacement is Ww and the noise is soft.
The operation of and use of the set after start is same as other Cummins regulators.
3. Operation methods.
3.1. Apearance Feature: It is same as other Cummins regulators.
3.2. Switchesc: Seitches for after start while all the 3 switches downside, it can ccelerate immediately, while switch them upside respectively. It can accelerate in 5´ , 10´ , 15respectively.
As the picture described (7-10 cannot connect prompt switches). The time more needs the smoke thinner and much easier to start.
3.3. The lasting time of the start switch vibration is a little wag...
During acceleration, if there is displacement stroke and displace black smoke, please regulate GAIN.
3.4. If the sets adopt self—start such as British DS520, 560, 5110 etc, and if it stops from start to idle speed over10´ , please spend more time to start according to the manual, All the self-start have the protection function of stopping after failing to self -start 3 times.
If it cannot start first time, the second time can be successful.

Detail more >>
Cummins Control Panel 3053065/Speed Controller/idle speed control valve/speed control

Cummins Control Panel 3053065/Speed Controller/idle speed control valve/speed control

Cummins Control Panel 3053065/Speed Controller/idle speed control valve/speed control

Cummins Control Panel 3053065
Speed Controller for Cummins Engine

Cummins Control Panel 3053065/Speed Controller/idle speed control valve/speed control

Product Description

Model:
3044195
3044196
3032733
3037359
4914091
4914090
3062322
3062323
3053061
3053065

We supply the above model control panel which can fit on cummins engine. If you have any further information about that, pls contact us. 

Detail more >>
You may also be interested in:GAC SPEED CONTROLSC-63 Idle speed control motor TesterGAC speed controller ESD5221EGAC speed controller ESD5522Eelectric motor speed controlElectric Speed Controller
Talk with SupplierX
Zheng Anna:
Can I help you?
Contact Supplier

Selected(1/4)Contact or Compare