Related Searches : SF6 Circuit BreakerOutdoor SF6 Circuit Breakeroutdoor hv sf6 circuit breaker12kV Circuit Breaker Used Glass Vacuum InterrupterCircuit Breakers110KV Power Transformer

110 kv SF6 Circuit Breaker

  • 1 Set/Sets
  • SF6
  • shanghai port
  • Circuit Breaker
  • China (Mainland)
  • Tag:circuit breaker
  • Supplier - CCC (Beijing) Industrial & Commercial Co., Ltd.
  • China (Mainland)China (Mainland)
  • US$10 Million - US$50 Million
  • 51 - 100 People
  • Manufacturer, Trading Company, Agent
  • North America,South America,Eastern Europe,Southeast Asia,Africa,Mid East,Eastern Asia,Western Europe
  •   
  • Mr.John
  • 86-10-67670552
Post Date : May 13
Product Details
Company Profile

Item specifics

SF6
shanghai port
Circuit Breaker
China (Mainland)
200 Set/Sets per Month
L/C,T/T

Specifications

110 kv SF6 Circuit Breaker

1. Work Condition:

Daily temperature variation: ≤ 25 º C;

Sunshine: 0.1w/cm²

Pollution level: III (25mm/kV) and IV(31mm/kV);

Protection degree: IP5XW;

2.Technical Parameter:

Altitude: 1000m

Rate Voltage: 126kv

Rate Frequency: 50 HZ

Rated Current: 3150 A

Rated short –time withstands current : 31.5kA 40kA

Rated short –time withstands continuous time : 4s

Company Related ProductsView the Seller's Products
330KV  THREE WINDING POWER TRANSFORMER

330KV THREE WINDING POWER TRANSFORMER

330KV THREE WINDING POWER TRANSFORMER

High reliability ; low power loss; low operation cost;

Power-TransformersTechnical Parameters
1. 150MVA - 360MVA Two-winding or three -winding Transformer with On-load Tap-changer
2. Rated Capacity (KVA): 150000~360000 KVA
3.Vecor Group: Ynd11
4.Impedance Voltage (%): 14-15% )
5.Frequency: 50Hz
6.Cooling method: ONAN or ONFN
7.IEC60076 Power transformer

Service conditions
1.The height above the sea level is below 1000m;
2.Ambient temperature: +40º C--- -30º C;
3. Suitable for indoor and outdoor

Detail more >>
220 kV  AUTO TRANSFORMER

220 kV AUTO TRANSFORMER

220 kV AUTO TRANSFORMER

Power Transformer has the features of low-noise, low-partial discharge, low-temperature rise, shock-resistance,

Power-TransformersTechnical Parameters
1. 31500~360000KVA Two-winding Transformer

2. Rated Capacity (KVA): 31500~360000KVA

3.Vecor Group: Ynd11
4.Impedance Voltage (%): 12-14%
5.Frequency: 50Hz
6.Number of phases: 3
7.Cooling method: ONAN or ONFN
8.IEC60076 Power transformer
Operating condition
1.The height above the sea level is below 1000m;
2.Ambient temperature: +40º C--- -30º C;

Detail more >>
You may also be interested in:110kv cable110kv current transformerNS CIRCUIT BREAKERoutdoor Circuit breakerABB Circuit BreakerCircuit Breaker Lockout
Talk with SupplierX
yang John:
Can I help you?
Contact Supplier

Selected(1/4)Contact or Compare